28

2022

-

04

Annual Environmental Information Report of Hubei Gedian Renfu Pharmaceutical Accessories Co., Ltd.


Hubei Gedian Renfu Pharmaceutical Accessories Co., Ltd.

Annual Environmental Information Report

Key pollutant discharge units:Waste water belongs to the key sewage unit, and waste gas does not belong to the key sewage unit.

Basic information of the 1. and operation company, including basic information on enterprise production and ecological environment protection.

Hubei Gedian Renfu Pharmaceutical Excipients Co., Ltd. is a pharmaceutical enterprise mainly engaged in the research and development, production and sales of pharmaceutical excipients.Hubei Gedian Pharmaceutical Accessories Co., Ltd. is located in Gedian, Ezhou Cityeconomic technologyDevelopment ZoneConstruction Avenue199No., inIt was formally established on June 25, 2012 with a registered capital of 50 million yuan and legal representative:Zhang Yangyang,Organization Code:91420700597187612X,Current stageMainProducts and Scaleas follows:

1. Propylene Glycol 300 tons/year;

2. Sodium benzoate   150 tons/year;

(3)Oxcarbazepine  150tons/year.

The company's main buildings include: API production workshop1, 1 auxiliary material production workshop, 1 quality inspection building, 1 comprehensive building, 1 sewage treatment station, 2 Class A warehouses, 1 Class C warehouse, 1 power and maintenance center, and 1 tank farm. At present, the company has EHS production leading group, safety and environment director, safety and environment department consists of 7 personnel.

    The company's main waste production projects for waste water, waste gas. Among them, the treatment capacity of the sewage treatment station of this project can be500m3/d, the treatment process is "high concentration wastewater catalytic oxidation neutralization regulation primary sedimentation tank hydrolytic acidification anaerobic A/O secondary sedimentation tank air flotation tank". After the wastewater reaches the standard, it is discharged into the sewage pipe network of the park and finally into Gedian Sewage Treatment Plant for advanced treatment. The tail water meets the Class A standard of "Pollutant Discharge Standard for Urban Sewage Treatment Plant" and is discharged into Gedian Section of Ezhou Yangtze River. The waste gas treatment process is alkaline washing and washing biological drip filtration.

 

2. enterprise environmental management information, including ecological environment administrative licensing,Environmental protection tax, environmental pollution liability insurance, environmental protection credit evaluation.and other aspects of information

Environmental Impact Assessment of (I) Construction Projects and Other Environmental Protection Administrative Licenses

The company strictly abides by the Environmental Impact Assessment Law, and implements project environmental impact assessment for new or expansion projects to ensure compliance.The "three simultaneous" principle. During the reporting period, the pollutant discharge permits of the above-mentioned key pollutant discharge units were within the validity period and discharged pollutants in strict accordance with the provisions of the pollutant discharge permits. The details are as follows:

Gedian medicine auxiliarySewage Permit No.91420700597187612X001P,ValidDecember 27, 2025.

 

(II) environmental protection tax, environmental pollution liability insurance, environmental protection credit evaluation.

1.environmental protection tax

Hubei Ge Dian RenfuLimited pharmaceutical excipientsThe environmental protection tax payment of the responsible company shall meet the relevant document requirements of the state, Hubei provincial government and Ezhou city.

2. Environmental pollution liability insurance

According to the requirements of relevant national laws and regulations, Hubei Ge Dian RenfuLimited pharmaceutical excipientsLiability Company Insuredenvironmental pollution liability insurance.

3. Environmental credit evaluation

Hubei Ge Dian RenfuLimited pharmaceutical excipientsLiability Companyenvironmental protection credit evaluationGood, no deduction.

 

Information on the generation, treatment and discharge of 3. pollutants, including pollution prevention and control facilities, pollutant discharge, discharge of toxic and harmful substances, generation, storage, flow direction, utilization and disposal of industrial solid waste and hazardous waste, and self-monitoring, etc.

(I) Pollutant Generation, Treatment and Emission Information

Gedian medicine auxiliary

COD

Discharge after sewage collection and treatment

1 total sewage discharge outlet, located in the northeast of the plant area

4.84-264mg/L

4.854t

None

500mg/L

11.27t/a

ammonia nitrogen

0.183-23mg/L

0.53t

None

35mg/L

2.45t/a

VOCs

Discharge after treatment

1General exhaust outlet, located in the northeast of the plant area

ND-1.52mg/m3

0.028t

None

100mg/m3

14.4t/a

Methanol

ND-2.88mg/m3

0.126t

None

190mg/m3

None

HW02 Oleic Acid Intermediate,Tween intermediate,hydrotalcite,Activated Carbon

Entrust qualified units to handle

Huaxin Renewable Resources Utilization Co., Ltd., Hubei Zhongyou Youyi Environmental Protection Technology Group Co., Ltd., Hubei Runheng Environmental Technology Co., Ltd.

Not applicable

63.685t

None

Not applicable

None

HW49 activated sludge

Not applicable

28.28t

None

Not applicable

None

HW49 detection waste liquid,Packaging Materials

Not applicable

4.755t

None

Not applicable

None

 

Construction and operation of (II) pollution prevention facilities

The company strictly abides by national environmental protection laws and regulations, attaches great importance to environmental protection work, and carries out production and business activities in strict accordance with national environmental protection requirements; actively promotes equipment optimization and technological innovation to reduce the total discharge of pollutants; establishes a sound environmental protection system to improve all levels The environmental awareness of personnel. During the reporting period, the above-mentioned key sewage units all built their own sewage treatment, waste gas treatment and hazardous waste storage facilities, and the environmental protection facilities were operating normally and meeting the discharge standards. The specific situation is as follows:

Gedian medicine is supplemented1 set of sewage treatment system and 2 sets of waste gas treatment device. The design processing capacity of the sewage treatment system is 600t/d. The sewage treatment process adopts anaerobic composite circulating granular sludge suspension bed A/O, and is networked with the Hubei Provincial Department of Ecological Protection for real-time monitoring, and the wastewater is discharged up to the standard. The design processing capacity of the exhaust gas treatment device is 20000m.3/h, using acid wash alkali wash catalytic process biological drip filtration, after treatment to meet the discharge standards. Workshop closed treatment system for centralized collection and treatment of unorganized waste gas in the workshop, with a design treatment capacity of 170000m.3/h,Alkaline washingWater washing process.

(III) environmental self-monitoring programme

The above-mentioned key pollutant discharge units have formulated environmental self-monitoring plans and entrusted qualified testing units to test waste water, waste gas and noise in accordance with the requirements of the plan. The details are as follows:

Gedian medicine auxiliaryAccording to the relevant management measures of Hubei Province and the Ecological Bureau of Ezhou City, it is formulated on schedule.Self-monitoring programmeAnd reported to the Environmental Protection Bureau of Gedian Development Zone for the record, waste water, waste gas andThe monitoring of noise is entrusted to a qualified testing unit, Wuhan Zhongground Testing Technology Co., Ltd., to carry out testing according to the requirements of the plan. Wastewater testing items:pH value, COD, ammonia nitrogen, total phosphorus, hexavalent chromium, petroleum, animal and vegetable oils, suspended solids, five-day biochemical oxygen demand, flow rateExhaust gas detection items: particulate matter, sulfur dioxide, nitrogen oxides, odor concentration, hydrogen sulfide, ammonia, non-methane total hydrocarbons, methanol and volatile organic compounds, etc.; noise detection. The test results meet the requirements of relevant national standards.

 

4.Carbon emission information, including information on emissions, emission facilities, etc.

Hubei Gedian Renfu Pharmaceutical Accessories Co., Ltd.In 2021, natural gas consumption was 21703 cubic meters and electricity consumption was 2.97768 million kilowatt hours.

5. ecological and environmental emergency information, including emergency plans for environmental emergencies,Emergency Response to Heavy Pollution Weatherand other aspects of information

Emergency plan for (I) environmental emergencies

The above-mentioned key pollutant discharge units have completed the preparation of the "Emergency Plan for Environmental Emergencies" or related systems and filed with the local environmental protection department. The details are as follows:

Gedian medicine auxiliary preparationEmergency Plan for Environmental Accidents (Revised Edition)202111Month in Ezhou City Ecological Environment Bureau Gedian Branch for the record (record number:420703-2021-132M),Hazardous waste prevention measures emergencyThe Plan in2022YearJanuaryFiling at the Environmental Protection Bureau of Gedian Economic and Technological Development Zone (no record number),There were no environmental emergencies during the reporting period.

Emergency response to heavy pollution weather in (II)

Gedian medicine auxiliary preparationHeavy pollution weather performance grading materials"In2021October deliveryEzhou City Ecological Environment Bureau Gedian Branch for the record,Implement the corresponding heavy pollution weather emergency response plan according to the performance grading materials.

6. ecological environment illegal information

  No ecological and environmental violations occurred in 2021.

Legal disclosure of temporary environmental information in 7. this year

Timely and public disclosure of temporary environmental information in accordance with the law.

Other environmental information required by 8. laws and regulations

Complete the implementation report of sewage permit, pollution source monitoring information, hazardous waste management plan, environmental emergency plan information, environmental information statistics and other related environmental information reporting and disclosure work.